Prepared For:
Joe Blowe
Property Address:
1234 Main St.
Anytown, IL 60016
![]() |
| Date: 2/23/2005 | Time: 11:22 AM | Report ID: 22305 |
| Property: 1234 Main St. Anytown, IL 60016 |
Customer: Joe Blowe |
Real Estate Professional: Jane Doe A-One Real Estate |
Comment Key or Definitions
The following definitions of comment descriptions represent this inspection report. All comments by the inspector should be considered before purchasing this home. Any recommendations by the inspector to repair or replace suggests a second opinion or further inspection by a qualified contractor. All costs associated with further inspection fees and repair or replacement of item, component or unit should be considered before you purchase the property.
Inspected (IN) = I visually observed the item, component or unit and if no other comments were made then it appeared to be functioning as intended allowing for normal wear and tear.
Not Inspected (NI)= I did not inspect this item, component or unit and made no representations of whether or not it was functioning as intended and will state a reason for not inspecting.
Not Present (NP) = This item, component or unit is not in this home or building.
Repair or Replace (RR) = The item, component or unit is not functioning as intended or needs further inspection by a qualified contractor. Items, components or units that can be repaired to satisfactory condition may not need replacement.
| Age Of Home: Over 50 Years |
Home Faces: South |
Client Is
Present: No |
| Radon Test: No |
Water Test: No |
Weather: Clear |
| Temperature: Below 40 |
Rain in last 3
days: No |
| ROOF COVERING: AGED 3-TAB FIBERGLASS |
VIEWED ROOF COVERING
FROM: GROUND |
SKY LIGHT (S): NONE |
| CHIMNEY (exterior): BRICK |
| IN | NI | NP | RR | ||
| 1.0 | ROOF COVERINGS | X | |||
| 1.1 | FLASHINGS | X | |||
| 1.2 | SKYLIGHTS, CHIMNEYS AND ROOF PENETRATIONS | X | X | ||
| 1.3 | ROOFING DRAINAGE SYSTEMS | X | X | ||
| IN | NI | NP | RR | ||
![]() 1.1 Picture 1 |
![]() 1.2 Picture 1 |
![]() 1.2 Picture 2 |
![]() 1.2 Picture 3 |
![]() 1.2 Picture 4 |
![]() 1.3 Picture 1 |
![]() 1.3 Picture 2 |
| SIDING STYLE: BEVEL |
SIDING MATERIAL: VINYL |
EXTERIOR ENTRY DOORS: WOOD STEEL |
| APPURTENANCE: AGED DECK WITH STEPS |
GARAGE DOOR MATERIAL: FIBERGLASS |
GARAGE DOOR TYPE: TWO MANUAL |
| DRIVEWAY: ASPHALT |
| IN | NI | NP | RR | ||
| 2.0 | WALL CLADDING FLASHING AND TRIM | X | X | ||
| 2.1 | DOORS (Exterior) | X | |||
| 2.2 | WINDOWS | X | |||
| 2.3 | GARAGE DOOR OPERATORS (Report whether or not doors will reverse when met with resistance) | X | |||
| 2.4 | DECKS, BALCONIES, STOOPS, STEPS, AREAWAYS, PORCHES AND APPLICABLE RAILINGS | X | X | ||
| 2.5 | EAVES, SOFFITS AND FASCIAS | X | |||
| IN | NI | NP | RR | ||
![]() 2.0 Picture 1 |
![]() 2.1 Picture 1 |
![]() 2.1 Picture 2 |
![]() 2.1 Picture 3 |
![]() 2.2 Picture 1 |
![]() 2.2 Picture 2 |
![]() 2.4 Picture 1 |
![]() 2.4 Picture 2 |
| ATTIC INSULATION: AGED BLOWN BATT |
VENTILATION: GABLE VENTS |
DRYER POWER SOURCE: GAS CONNECTION |
| IN | NI | NP | RR | ||
| 3.0 | INSULATION AND VAPOR RETARDERS (in unfinished spaces) | X | |||
| 3.1 | VENTILATION OF ATTIC AND FOUNDATION AREAS | X | |||
| 3.2 | VENTING SYSTEMS (Kitchens, baths and laundry) | X | |||
| 3.3 | VENTILATION FANS AND THERMOSTATIC CONTROLS (ATTIC) | X | |||
| IN | NI | NP | RR | ||
![]() 3.0 Picture 1 |
![]() 3.2 Picture 1 |
| CEILING MATERIALS: AGED PLASTER |
WALL MATERIAL: AGED PLASTER |
FLOOR COVERING(S): AGED TILE VINYL WOOD |
| INTERIOR DOORS: AGED WOOD |
WINDOW TYPES: THERMAL/INSULATED DOUBLE-HUNG |
WINDOW MANUFACTURER: UNKNOWN |
| CABINETRY: AGED WOOD |
COUNTERTOP: AGED LAMINATE |
| IN | NI | NP | RR | ||
| 4.0 | CEILINGS | X | X | ||
| 4.1 | WALLS | X | X | ||
| 4.2 | FLOORS | X | X | ||
| 4.3 | STEPS, STAIRWAYS, BALCONIES AND RAILINGS | X | X | ||
| 4.4 | COUNTERS AND A REPRESENTATIVE NUMBER OF CABINETS | X | |||
| 4.5 | DOORS (REPRESENTATIVE NUMBER) | X | X | ||
| 4.6 | WINDOWS (REPRESENTATIVE NUMBER) | X | |||
| IN | NI | NP | RR | ||
![]() 4.0 Picture 1 |
![]() 4.1 Picture 1 |
![]() 4.2 Picture 1 |
![]() 4.3 Picture 1 |
![]() 4.5 Picture 1 |
| FOUNDATION: BRICK |
METHOD USED TO OBSERVE
CRAWLSPACE: NO CRAWLSPACE |
FLOOR STRUCTURE: 2 X 8 |
| WALL STRUCTURE: 2 X 4 WOOD |
COLUMNS OR PIERS: SUPPORTING WALLS |
CEILING STRUCTURE: NOT VISIBLE |
| ROOF STRUCTURE: 2 X 6 RAFTERS |
METHOD USED TO OBSERVE
ATTIC: WALKED |
ATTIC INFO: SCUTTLE HOLE |
| IN | NI | NP | RR | ||
| 5.0 | FOUNDATIONS (Report signs of abnormal or harmful water penetration into the building or signs of abnormal or harmful condensation on building components.) | X | X | ||
| 5.1 | WALLS (Structural) | X | |||
| 5.2 | COLUMNS OR PIERS | X | |||
| 5.3 | FLOORS (Structural) | X | X | ||
| 5.4 | CEILINGS (structural) | X | |||
| 5.5 | ROOF STRUCTURE AND ATTIC | X | |||
| IN | NI | NP | RR | ||
![]() 5.0 Picture 1 |
![]() 5.0 Picture 2 |
| WATER SOURCE: PUBLIC |
PLUMBING SUPPLY: AGED COPPER |
PLUMBING
DISTRIBUTION: GALVANIZED COPPER |
| PLUMBING WASTE: PVC GALVANIZED CAST IRON (OLD) |
WATER HEATER POWER
SOURCE: GAS (QUICK RECOVERY) |
CAPACITY: 50 GAL (2-3 PEOPLE) |
| IN | NI | NP | RR | ||
| 6.0 | INTERIOR DRAIN, WASTE AND VENT SYSTEMS | X | X | ||
| 6.1 | INTERIOR WATER SUPPLY AND DISTRIBUTION SYSTEMS AND FIXTURES | X | |||
| 6.2 | HOT WATER SYSTEMS, CONTROLS, CHIMNEYS, FLUES AND VENTS | X | |||
| 6.3 | MAIN WATER SHUT-OFF DEVICE (Describe location) | X | |||
| 6.4 | FUEL STORAGE AND DISTRIBUTION SYSTEMS (Interior fuel storage, piping, venting, supports, leaks) | X | |||
| 6.5 | SUMP PUMP | X | |||
| IN | NI | NP | RR | ||
![]() 6.0 Picture 1 |
![]() 6.0 Picture 2 |
![]() 6.0 Picture 3 |
![]() 6.1 Picture 1 |
| ELECTRICAL SERVICE
CONDUCTORS: OVERHEAD SERVICE |
ELEC. PANEL
MANUFACTURER: Unknown |
BRANCH WIRE 15 and 20
AMP: COPPER |
| WIRING METHODS: ROMEX CONDUIT |
| IN | NI | NP | RR | ||
| 7.0 | SERVICE ENTRANCE CONDUCTORS | X | |||
| 7.1 | SERVICE AND GROUNDING EQUIPMENT, MAIN OVERCURRENT DEVICE, MAIN AND DISTRIBUTION PANELS | X | |||
| 7.2 | BRANCH CIRCUIT CONDUCTORS, OVERCURRENT DEVICES AND COMPATIBILITY OF THEIR AMPERAGE AND VOLTAGE | X | |||
| 7.3 | CONNECTED DEVICES AND FIXTURES (Observed from a representative number operation of ceiling fans, lighting fixtures, switches and receptacles located inside the house, garage, and on the dwelling's exterior walls) | X | X | ||
| 7.4 | POLARITY AND GROUNDING OF RECEPTACLES WITHIN 6 FEET OF INTERIOR PLUMBING FIXTURES, AND ALL RECEPTACLES IN GARAGE, CARPORT, EXTERIOR WALLS OF INSPECTED STRUCTURE | X | X | ||
| 7.5 | OPERATION OF GFCI (GROUND FAULT CIRCUIT INTERRUPTERS) | X | |||
| 7.6 | LOCATION OF MAIN AND DISTRIBUTION PANELS | X | X | ||
| 7.7 | SMOKE DETECTORS | X | |||
| IN | NI | NP | RR | ||
![]() 7.3 Picture 1 |
![]() 7.3 Picture 2 |
![]() 7.3 Picture 3 |
![]() 7.3 Picture 4 |
![]() 7.3 Picture 5 |
![]() 7.3 Picture 6 |
![]() 7.3 Picture 7 |
![]() 7.4 Picture 1 |
![]() 7.6 Picture 1 |
| HEAT TYPE: FORCED AIR |
ENERGY SOURCE: GAS |
NUMBER OF HEAT SYSTEMS (excluding
wood): ONE |
| TYPES OF FIREPLACES: NONE |
OPERABLE FIREPLACES: NONE |
NUMBER OF WOODSTOVES: NONE |
| IN | NI | NP | RR | ||
| 8.0 | HEATING EQUIPMENT | X | X | ||
| 8.1 | NORMAL OPERATING CONTROLS | X | |||
| 8.2 | CHIMNEYS, FLUES AND VENTS | X | |||
| 8.3 | SOLID FUEL HEATING DEVICES | X | |||
| 8.4 | HEAT DISTRIBUTION SYSTEMS (including fans, pumps, ducts and piping, with supports, insulation, air filters, registers, radiators, fan coil units and convectors) | X | |||
| 8.5 | GAS/LP FIRELOGS AND FIREPLACES | X | |||
| 8.6 | PRESENCE OF INSTALLED HEAT SOURCE IN EACH ROOM | X | |||
| IN | NI | NP | RR | ||
![]() 8.0 Picture 1 |
| COOLING EQUIPMENT
TYPE: AIR CONDITIONER UNIT |
COOLING EQUIPMENT ENERGY
SOURCE: ELECTRICITY |
NUMBER OF A/C UNITS: ONE |
| IN | NI | NP | RR | ||
| 9.0 | COOLING AND AIR HANDLER EQUIPMENT | X | |||
| 9.1 | NORMAL OPERATING CONTROLS | X | |||
| 9.2 | DISTRIBUTION SYSTEMS (including fans, pumps, ducts and piping, with supports, insulation, air filters, registers, radiators, fan coil units and convectors) | X | |||
| 9.3 | PRESENCE OF INSTALLED COOLING SOURCE IN EACH ROOM | X | |||
| IN | NI | NP | RR | ||
| TRASH COMPACTORS: NONE |
| IN | NI | NP | RR | ||
| 10.0 | DISHWASHER | X | |||
| 10.1 | RANGES/OVENS/COOKTOPS | X | |||
| 10.2 | RANGE HOOD | X | |||
| 10.3 | TRASH COMPACTOR | X | |||
| 10.4 | FOOD WASTE DISPOSER | X | |||
| 10.5 | MICROWAVE COOKING EQUIPMENT | X | |||
| IN | NI | NP | RR | ||
![]() Accurate Home Inspections NW Corp 2303 Magnolia St. | |
|
Customer | |
|
Home | |
| 1.2 | SKYLIGHTS, CHIMNEYS AND ROOF PENETRATIONS | ||||
| Inspected, Repair or Replace | |||||
|
If metal flashing exists I could not see it
due to tar smeared all over chimney. Their is evidence of many leaks
around the chimney from the inside that are old. Recommend inspection of
this area by a qualified licenced roofing contractor.
| |||||
| 1.3 | ROOFING DRAINAGE SYSTEMS | ||||
| Inspected, Repair or Replace | |||||
|
Downspout is damaged at front right corner of
home. This could cause water backup and may add to water penetration at
foundation.. Recommend repair or replace as needed using a qualified
person.
| |||||
| 2.0 | WALL CLADDING FLASHING AND TRIM | |
| Inspected, Repair or Replace | ||
|
Vinyl siding at left side (facing front) is
missing. Further deterioration can occur if not corrected. Recommend
repair or replace as needed using a qualified person.
| ||
| 2.4 | DECKS, BALCONIES, STOOPS, STEPS, AREAWAYS, PORCHES AND APPLICABLE RAILINGS | |
| Inspected, Repair or Replace | ||
|
Structural posts appear to be in ground
surrounded by concrete instead of sitting on piers. This will cause the
posts to decay and rot.
| ||
| 2.4 | DECKS, BALCONIES, STOOPS, STEPS, AREAWAYS, PORCHES AND APPLICABLE RAILINGS | |
| Inspected, Repair or Replace | ||
|
Piers on the front porch appear to have sunk
causing the pitch down at each end, recommend inspection from a structural
engineer.
| ||
| 4.0 | CEILINGS | |
| Inspected, Repair or Replace | ||
|
The ceiling in east bedroom is bowed and may
be a safety concern. Recommend inspection by a qualified contractor.
| ||
| 4.1 | WALLS | |
| Inspected, Repair or Replace | ||
|
Surround kit at bathtub on wall is
deteriorated and needs repair at Lower Level Bath. Repairs are needed to
prevent water damage from shower/bath. Recommend a qualified contractor
inspect and repair as needed.
| ||
| 4.2 | FLOORS | |
| Inspected, Repair or Replace | ||
|
Floors in South bedroom and kitchen are
unlevel in many areas, recommend a structural engineer inspect.
| ||
| 4.3 | STEPS, STAIRWAYS, BALCONIES AND RAILINGS | |
| Inspected, Repair or Replace | ||
|
Blasters are missing at stairs to upstairs,
this is a safety defect and should be repaired immediately by a qualified
contractor.
| ||
| 4.5 | DOORS (REPRESENTATIVE NUMBER) | |
| Inspected, Repair or Replace | ||
|
Door knobs are missing through out the house.
A person could get trapped in a room/closet by not being able to turn
the striker. This is a safety defect and should be
repaired immediately by a qualified person.
| ||
| 5.0 | FOUNDATIONS (Report signs of abnormal or harmful water penetration into the building or signs of abnormal or harmful condensation on building components.) | ||
| Inspected, Repair or Replace | |||
|
Visible signs of water intrusion in basement
are present on brick foundation.. Water intrusion can lead to more costly
repairs and increase damage if not corrected. Recommend further
investigation or correction by a qualified licensed contractor or water
infiltration specialist.
| |||
| 5.3 | FLOORS (Structural) | ||
| Inspected, Repair or Replace | |||
|
Please refer to interior
section. | |||
| 6.0 | INTERIOR DRAIN, WASTE AND VENT SYSTEMS | ||
| Inspected, Repair or Replace | |||
|
Open vent lines vent into the attic, this is a
defect and can cause moisture buildup and mold in attic and should be
repaired by a qualified licenced plumber.
| |||
| 7.3 | CONNECTED DEVICES AND FIXTURES (Observed from a representative number operation of ceiling fans, lighting fixtures, switches and receptacles located inside the house, garage, and on the dwelling's exterior walls) | ||||
| Inspected, Repair or Replace | |||||
|
Ceiling fan does not have a proper mounting
box in Bedroom. Electrical issues are considered a hazard until
repaired. Recommend a qualified licensed electrician perform repairs that
involve wiring.
| |||||
| 7.3 | CONNECTED DEVICES AND FIXTURES (Observed from a representative number operation of ceiling fans, lighting fixtures, switches and receptacles located inside the house, garage, and on the dwelling's exterior walls) | ||||
| Inspected, Repair or Replace | |||||
|
Their are many open electrical boxes
throughout the house and wiring uncovered by insulation. Recommend all
electrical system be inspected and repaired by qualified licenced
electrician.
| |||||
| 7.4 | POLARITY AND GROUNDING OF RECEPTACLES WITHIN 6 FEET OF INTERIOR PLUMBING FIXTURES, AND ALL RECEPTACLES IN GARAGE, CARPORT, EXTERIOR WALLS OF INSPECTED STRUCTURE | ||||
| Inspected, Repair or Replace | |||||
|
Outlet in bathroom is within 3' of plumbing
fixture and is not GFCI, recommend replace by a qualified licenced
electrician.
| |||||
| 8.0 | HEATING EQUIPMENT | |
| Inspected, Repair or Replace | ||
|
Furnace is very old but did work at time of
inspection. Unable to determine life remaining.
| ||
Prepared Using HomeGauge http://www.homegauge.com/ SHGI (c)
2000-2004 : Licensed To Accurate Home Inspections NW Corp
1.0 Picture 1